METHOD AND APPARATUS FOR MELTING SNOW AND ICE - …

Jan 21, 2008 · In one embodiment, the present invention seeks to provide a method of de-icing, melting and thawing surfaces, snow and ice and frozen ground, comprising: heating an aqueous liquid in a boiler to a high temperature below the boiling point; directing said heated liquid into a series of nozzles in a closed plenum; blowing ambient air into said

Read more

680 - tekmar - Watts

Upon detection of snow or ice, the 680 operates an electric heating cable, a single hydronic condensing or non-condensing boiler, or a steam valve to provide heat to the snow melt load. The 680 provides boiler return protection by operating a …

Read more

Principals of Condensing Boiler System Design

boiler efficiency curve from a manufacture and a theoretical performance curve. Figure 1 Typical Condensing Boiler Efficiency Curves The boiler starts to condense water out of the combustion gasses when the dewpoint of the combustion gasses is reached; which, at …

Read more

Strainers for Hydronic Applications | US Boiler Report May

May 28, 2020 · Boiler ink has magnetite, which is a thin protective layer on the cast and piping. When this layer starts to get suspended in the water it needs to be removed. The pumps and the condensing heat exchangers with smaller passageways can be affected by this suspended ferrous material. This is why we need strainers!

Read more

Approx snow melt BTUs - Heating Help: The Wall

Jun 01, 2007 · We have a new customer with a boiler that serves 3 infloor zones and a 4th zone wired to a switch. We can't figure out and customer is new to the house, what that 4th zone is. Tech thinks it is snowmelt for 100+ foot long driveway. Seems to me the 150K boiler is sized right for the house and couldn't make a dent in the drive.

Read more

Method and apparatus for melting snow and ice - Chinook

The invention claimed is: 1. An apparatus for melting snow, ice and frozen ground comprising: a boiler adapted to heat a liquid to a temperature below the boiling point; a first circulating pump; an outlet line; an inlet line; a series of enclosed coils adapted to carry said liquid through a plenum-type housing; a separate water supply and a second circulating pump adapted to carry water to

Read more

Snowmelt 101 | Contracting Business

Feb 22, 2005 · Generally, supply water in the 80F to 140F range will handle any snow or ice melting task. Choose and size the boiler accordingly, and use the lowest temperature necessary for your area. This will save the customer money on fuel costs, and extend the life of the concrete by avoiding extreme temperature swings.

Read more

hydronic heated driveway system: Outdoor Boiler melting

Call Ted at Abbott Boiler Supply for all of your ice melt and snow melting needs. 828-687-4074. He has a much better insulation product. Heated Driveways, Driveway Heating, How to Heat a Driveway, Snow and Ice Melting, Radiant Heat, Driveway Deicing, Heated Walkway, Snow Melt, Ice Melt, Heated Sidewalk.

Read more

Janes Radiant - Hot Water Radiant Systems

Lochinvar Combination Boiler. -Like two devices in one: Modulating boiler for heat and instant hot water function for domestic uses. -These high efficiency combi boilers are available for natural gas or propane. -Three sizes to fit most any project: 110,000 BTU's, 150,000 BTU's or 199,000 BTU's. -Wall-hung to conserve floor space.

Read more

Products - Brazetek

For larger size hydronic heating projects, radiant heating, indoor and outdoor wood boilers, larger snow melting systems, domestic hot water heating and other applications that require higher flow rates and high efficiency ratios, a 5x12 brazed plate heat exchanger is the optimal choice. Available in 50, 60, 70 & 80-plate models.

Read more

Snow Melting Systems - Engineering ToolBox

This 399,000btu Triangle Tube Prestige Solo ACVMax boiler melts a 2,400 sq. ft. driveway at a Castle Rock home. We installed 4,350′ of 5/8″ Uponor hePEX tubing for 3,000 sq. ft. of Driveway, Front Deck, and Back Patio snow-melt at a Winter Park home. A Tekmar 654 automatically controls the snow-melt system and there are four zones.

Read more

Radiant HEX PackageRadiant HEX Package - Cemline

piped including boiler water strainer, circuit setter, and boiler water balancing valve. Factory piping shall include a 3-way motorized tempering valve and inlet strainer on the snow melt side of the heat exchanger. Heat exchanger shall be single walled brazed copper brazed 316L stainless steel plate type.

Read more

Sizing Diaphragm-Type Expansion Tanks for - PM Engineer

Oct 06, 2003 · However, things change as the size of the system increases. For example, a few years ago I helped design a radiant floor heating system containing 21 miles of 3/4" PEX tubing. The floor circuits held approximately 2,100 gallons of fluid. The boilers and near boiler piping held about 225 gallons of fluid.

Read more

An Insight to Outdoor Boilers

Apr 27, 2018 · An Insight to Outdoor Boilers. Portage and Main manufactures boilers that can utilize different fuel sources such as wood, coal, or wood chips, wood pellets or other bio-mass. The boilers come in various model and sizes and generate varying amounts of BTU's. We look to size every boiler to the needed heat load for a given application or install.

Read more

Residential | NTI Boilers

The TRX is a high-efficiency, wall-hung boiler equipped with an Innovative XTRATECH® stainless steel heat…. TFT Series. The TFT is the top quality choice for both residential or light commercial applications. The…. NTI Compact. The high quality and affordable price of the NTI Compact mini tank electric water heater…. Lx Series.

Read more

Seasoned Wood - Portage & Main Outdoor Boilers

Portage and Main Outdoor Water Furnaces has taken the best design in the outdoor wood boiler industry and made it better with our revolutionary new series. Proper combustion in an outdoor wood boiler requires heat, fuel and oxygen. To provide the heat, Portage and Main outdoor water furnaces have incorporated the use of refractory cement and fire brick. 2 1/2 inches of …

Read more

Sizing a Gas-Fired Combi Boiler - GreenBuildingAdvisor

Feb 25, 2019 · A temperature rise of 70F (mid-winter 35F incoming, 105F at the shower heads) and 5 gpm (= 2500lb/hr) flow takes 70F x 2500lb/hr= 175,000 BTU/hr of burner output. That is clearly outside the max capacity of the W-M Aqua Balance 150, but within the range of the HTP UFTC-199 or Navien NCB-240E combi boilers.

Read more

The #1 Industrial Boiler Sizing Guide - Powerhouse

Since these types of boilers have different usages, there are certain inputs that matter more when estimating the size of your boiler. Note: Some facilities require redundancy while others operate on an N+1 scheme. This just means that the total load is split between N number of boilers and an additional boiler sits idle for availability

Read more

Snowmelting Boilers: The Condensed and Non - PM …

Due to the high flow rates and high BTU requirements of snowmelt systems,using the High-Capacity manifolds and ¾" Infloor tube is generally recommended. However, smaller diameter tubing may be used for systems with short tubing circuits, and larger diameter tubing may be used when extremely high flow rates or longer tube circuits are required.

Read more

QUICK SIZING CHARTS for BRAZED PLATE HEAT …

Boiler 2. Snow Melt Selections Example: For a snow melt system requiring 122,000 BTUh, select Model B5 with 20 Plates. If the GPM requirement of the snow melt system is greater than 9.0 GPM, use the next larger model to match the pump requirement. 0% P.G.) Boiler 180˚F in - …

Read more

Boiler Selection for Snow-Melt Systems - Contractor

Hydronic snowmelt systems - Plumbing & HVAC

Read more

Principals of Condensing Boiler System Design

boiler efficiency curve from a manufacture and a theoretical performance curve. Figure 1 Typical Condensing Boiler Efficiency Curves The boiler starts to condense water out of the combustion gasses when the dewpoint of the combustion gasses is reached; which, at …

Read more

Related Information